Flame Behaviour Comparison of Building Ceiling Composite using Combustion Calorimeter

dc.contributor.authorDirisu, J.O.
dc.contributor.authorFayomi, OSI.
dc.contributor.authorOyedepo, S.O
dc.contributor.authorOyekunle, J.A.O.
dc.contributor.authorAsere, A.A
dc.contributor.authorUdoye, N. E
dc.date.accessioned2022-06-01T11:42:13Z
dc.date.available2022-06-01T11:42:13Z
dc.date.issued2021
dc.descriptionStaff Publicationen_US
dc.description.abstractThis study determined the heat of combustion characteristics of selected building ceilings materials. The study was intending to appraise the flame affinity or retardance of building ceiling materials during combustion. Careful selection of ceiling composite was carried out in areas like Osun state, Ogun state, Lagos state, and Kaduna State. The heat of combustion was determined, having identified the heating value from the XRY-1C Oxygen Bomb Calorimeter. The heat flux and heat release rates were determined from the results of the combustion experiment. Based on the data obtained from the discrete experiments, the combustion integrity of the samples was appraised. Particleboard has the highest heat of combustion of 45.666J/kg, while asbestos failed to ignite. Other Polyvinyl chlorides (PVC) left ≤ 0.0007kg of char after combustion and became deliquescent after long minutes of exposure to air. The heat release rate is highest with particleboard, 118.9219 J/s, and lowest with sample 7, 2.230 J/s. The study thus establishes that PVC is safer in terms of combustion properties compared to plant-based building ceilings. Asbestos has the overall most reliable properties, but for asbestosis, its use isn't safe for use. It is necessary to develop building ceilings with flame retardant characteristics of asbestos as an alternative to it.en_US
dc.identifier.uridoi:10.1088/1757-899X/1107/1/012035
dc.identifier.urihttp://repository.elizadeuniversity.edu.ng/handle/20.500.12398/1386
dc.language.isoenen_US
dc.publisherIOP Conf. Series: Materials Science and Engineeringen_US
dc.subjectbuilding ceilings,en_US
dc.subjectcombustion,en_US
dc.subjectheat flux,en_US
dc.subjectheat release rate,en_US
dc.subjectsustainable developmenten_US
dc.titleFlame Behaviour Comparison of Building Ceiling Composite using Combustion Calorimeteren_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dirisu_2021_IOP_Conf._Ser.__Mater._Sci._Eng._1107_012035.pdf
Size:
2.24 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description: