Optimal model order selection for transient error autoregressive moving average (TERA) MRI reconstruction method
dc.contributor.author | Aibinu, Abiodun M. | |
dc.contributor.author | Najeeb, Athaur R. | |
dc.contributor.author | Salami, Momoh-Jimoh E. | |
dc.contributor.author | Shafie, Amir A. | |
dc.date.accessioned | 2019-08-14T14:12:49Z | |
dc.date.available | 2019-08-14T14:12:49Z | |
dc.date.issued | 2008-08 | |
dc.description.abstract | An alternative approach to the use of Discrete Fourier Transform (DFT) for Magnetic Resonance Imaging (MRI) reconstruction is the use of parametric modeling technique. This method is suitable for problems in which the image can be modeled by explicit known source functions with a few adjustable parameters. Despite the success reported in the use of modeling technique as an alternative MRI reconstruction technique, two important problems constitutes challenges to the applicability of this method, these are estimation of Model order and model coefficient determination. In this paper, five of the suggested method of evaluating the model order have been evaluated, these are: The Final Prediction Error (FPE), Akaike Information Criterion (AIC), Residual Variance (RV), Minimum Description Length (MDL) and Hannan and Quinn (HNQ) criterion. These criteria were evaluated on MRI data sets based on the method of Transient Error Reconstruction Algorithm (TERA). The result for each criterion is compared to result obtained by the use of a fixed order technique and three measures of similarity were evaluated. Result obtained shows that the use of MDL gives the highest measure of similarity to that use by a fixed order technique. | en_US |
dc.identifier.citation | Aibinu, A. M., Najeeb, A. R., Salami, M. J., & Shafie, A. A. (2008, August). Optimal model order selection for transient error autoregressive moving average (TERA) MRI reconstruction method. In International Conference on Medical system Engineering (ICMSE). | en_US |
dc.identifier.uri | http://repository.elizadeuniversity.edu.ng/handle/20.500.12398/465 | |
dc.language.iso | en | en_US |
dc.publisher | International Conference on Medical system Engineering (ICMSE) | en_US |
dc.subject | Autoregressive Moving Average (ARMA) | en_US |
dc.subject | Magnetic Resonance Imaging (MRI) | en_US |
dc.subject | Parametric modeling | en_US |
dc.subject | Transient Error | en_US |
dc.title | Optimal model order selection for transient error autoregressive moving average (TERA) MRI reconstruction method | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Optimal model order selection for transient error autoregressive moving average (TERA) MRI reconstruction method.pdf
- Size:
- 442.91 KB
- Format:
- Adobe Portable Document Format
- Description:
- Article full-text
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.61 KB
- Format:
- Item-specific license agreed upon to submission
- Description: